Lighting design & photometric services

Calculated.Coordinated.Buildable.

From professional reports to architectural layouts and renders, Stetra supports the full path from performance target to project handoff.

Get a project quote
01

Most requested

Photometric plans & permit reports

Code-focused photometric calculations for parking lots, warehouses, gas stations, car washes, signage, commercial sites, sports fields, and exterior projects.

  • Point-by-point foot-candle or lux grids
  • Min / average / max values and uniformity
  • Fixture schedule, mounting, optics, and aiming
  • Light trespass, shielding, and review corrections
02

Architecture

Lighting layouts & coordination

Complete fixture placement for residential, hospitality, workplace, retail, and mixed-use spaces—developed around function, architecture, and visual comfort.

  • Fixture placement and spacing
  • Mounting heights and aiming angles
  • Layered ambient, task, and accent lighting
  • Technical coordination with plans and reflected ceilings
03

Visualization

3D lighting renders

Realistic visual studies that show how the proposed lighting interacts with materials, architecture, shadow, and atmosphere before construction.

  • Interior and exterior scenes
  • Light distribution and shadow studies
  • Material response and color temperature
  • Client presentation visuals
04

Specification

Fixture & optics consulting

Independent guidance for fixture selection, lumen packages, beam angles, photometric files, glare control, and application suitability.

  • IES file and distribution review
  • Beam angle and optic selection
  • Lumen output and mounting coordination
  • Value-engineering alternatives
05

Compliance

Emergency, glare & code analysis

Targeted calculations for emergency lighting, UGR, BUG ratings, property-line spill, dark-sky requirements, and local illumination criteria.

  • Emergency lighting simulations
  • UGR and visual comfort review
  • BUG rating and uplight control
  • Property-line and trespass calculations
06

Special applications

Outdoor & sports lighting

Performance-focused calculations for courts, fields, façades, roadways, industrial sites, and large exterior areas where uniformity and glare matter.

  • Pole, floodlight, and aiming layouts
  • Uniformity and weak-zone analysis
  • Glare and spill-light control
  • False-color and 3D review views

Clear deliverables. Personal review. Fast turnaround.

1–2 daysTypical delivery with complete inputs

500+ projectsCommercial, site, sports, and architectural

Start with the files you already have.

01

Plan background

Scaled PDF, DWG, site plan, floor plan, or clear image.

02

Fixture information

IES files, cutsheets, model numbers, optics, and output.

03

Project criteria

Targets, mounting heights, deadlines, and review comments.

04

Known constraints

Property lines, shielding, code, glare, or spill-light limits.

Before you send the project.

Can you fix a photometric plan that failed review?

Yes. Send the previous plan and reviewer comments. We can adjust fixture layout, optics, shielding, and calculations around the specific issue.

Do I need to know the target light levels?

No. If a target or code requirement is available, include it. Otherwise, send the project type and location so the criteria can be reviewed.

Can you recommend fixtures and optics?

Yes. Stetra can review IES files, lumen packages, beam angles, mounting heights, shielding, and application suitability.

What format will I receive?

Deliverables are scoped per project and typically include a clear PDF report with the lighting layout, calculation grid, summary values, and relevant notes.

Send the plan. We’ll calculate the light.

Share your drawings, fixture schedule, and project targets. We’ll review the scope and confirm the right next step.

Request a photometric plan